Welcome to the official website of Shanghai Radk-Tech Hydraulic Control System Co., Ltd.

language
    RT4WRA
    RT4WRA
    +
    • RT4WRA
    • RT4WRA

    RT4WRA


    Two-position four-way and three-position four-way direct-acting proportional directional valves Valve core without displacement sensor

    Nominal Diameter: 6, 10
    Maximum Working Pressure: 315bar
    Maximum Flow Rate: 42L/min (Nominal Diameter 6)
    Maximum Flow Rate: 75L/min (Nominal Diameter 10)
    • Product Description

      Product Description

    • Function Description

      RT4WRA、RT4WRAE

      The 4/2- and 4/3-way proportional directional valves are designed as direct operated components for subplate mounting. They are actuated
      by means of proportional solenoids with central thread and removable coil. The solenoids are controlled either by external control electronics
      (type RT4WRA) or by integrated control electronics (type RT4WRAE).

      Design:
      The valves basically consist of:
      Housing (1) with mounting surface
      Control spool (2) with compression spring (3 and 4)
      Solenoid (5 and 6) with central thread
      Optional integrated electronics (7)

      Function:
      With the solenoids (5 and 6) de-energized, the control spool (2) is held in
      the central position by compression spring {3 and 4)
      Direct actuation of the control spool (2)) by energizing a proportional
      solenoid


      E.g. energization of solenoid "b" (6)
      ➔ The control spool (2) is moved to the left in proportion to the electrical
      input signal
      ➔ connection from P to A and B to T via orifice-like cross-sections with
      progressive flow characteristics
      De-energization of the solenoid (6)
      The control spool (2) is returned to the central position by compression
      spring(3)

      Valve with 2 spool positions:
      (Type RT4WRA ... A ... )
      In principle, the function of this valve version corresponds to that
      of the valve with 3 spool positions. However, the valves with 2 spool

      positions are only fitted with solenoid "a". Instead of the 2nd proportional solenoid a plug (8.1) is fitted for NS 6 or for NS 10 a cover (8.2).

      Note for type RT4WRA 6 ... -2X/ ... :
      Draining of the tank line is to be avoided. With the appropriate installation conditions, a back pressure valve is to be installed (back pressure
      approx. 2 bar).